Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(22): 221801, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38101357

RESUMO

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ^{127}I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of 9.2_{-1.8}^{+2.1}×10^{-40} cm^{2}. This corresponds to a value that is ∼41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on ^{127}I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be 5.2_{-3.1}^{+3.4}×10^{-40} and 2.2_{-0.5}^{+0.4}×10^{-40} cm^{2}, respectively.

2.
Phys Rev Lett ; 130(5): 051803, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800477

RESUMO

The COHERENT Collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220 MeV/c^{2} using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9 keV_{nr}. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6 kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants α_{D}<0.64, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

3.
Phys Rev Lett ; 129(8): 081801, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36053683

RESUMO

We measured the cross section of coherent elastic neutrino-nucleus scattering (CEvNS) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source at Oak Ridge National Laboratory. New data collected before detector decommissioning have more than doubled the dataset since the first observation of CEvNS, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT Collaboration determined the cross section to be (165_{-25}^{+30})×10^{-40} cm^{2}, consistent with the standard model, giving the most precise measurement of CEvNS yet. The timing structure of the neutrino beam has been exploited to compare the CEvNS cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino nonstandard interactions while testing lepton flavor universality and measures the weak mixing angle as sin^{2}θ_{W}=0.220_{-0.026}^{+0.028} at Q^{2}≈(50 MeV)^{2}.

4.
Phys Rev Lett ; 121(24): 242002, 2018 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-30608729

RESUMO

We report the first observation of the parity-violating gamma-ray asymmetry A_{γ}^{np} in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. A_{γ}^{np} isolates the ΔI=1, ^{3}S_{1}→^{3}P_{1} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless effective field theory. We measured A_{γ}^{np}=[-3.0±1.4(stat)±0.2(syst)]×10^{-8}, which implies a DDH weak πNN coupling of h_{π}^{1}=[2.6±1.2(stat)±0.2(syst)]×10^{-7} and a pionless EFT constant of C^{^{3}S_{1}→^{3}P_{1}}/C_{0}=[-7.4±3.5(stat)±0.5(syst)]×10^{-11} MeV^{-1}. We describe the experiment, data analysis, systematic uncertainties, and implications of the result.

5.
J Res Natl Inst Stand Technol ; 110(3): 195-203, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308121

RESUMO

The NPDGamma experiment will measure the parity-violating directional gamma ray asymmetry A γ in the reaction [Formula: see text]. Ultimately, this will constitute the first measurement in the neutron-proton system that is sensitive enough to challenge modern theories of nuclear parity violation, providing a theoretically clean determination of the weak pion-nucleon coupling. A new beam-line at the Los Alamos Neutron Science Center (LANSCE) delivers pulsed cold neutrons to the apparatus, where they are polarized by transmission through a large volume polarized (3)He spin filter and captured in a liquid para-hydrogen target. The 2.2 MeV gamma rays from the capture reaction are detected in an array of CsI(Tl) scintillators read out by vacuum photodiodes operated in current mode. We will complete commissioning of the apparatus and carry out a first measurement at LANSCE in 2004-05, which would provide a statistics-limited result for A γ accurate to a standard uncertainty of ±5 × 10(-8) level or better, improving on existing measurements in the neutron-proton system by a factor of 4. Plans to move the experiment to a reactor facility, where the greater flux would enable us to make a measurement with a standard uncertainty of ±1 × 10(-8), are actively being pursued for the longer term.

6.
J Res Natl Inst Stand Technol ; 110(3): 215-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308124

RESUMO

The NPDGamma γ-ray detector has been built to measure, with high accuracy, the size of the small parity-violating asymmetry in the angular distribution of gamma rays from the capture of polarized cold neutrons by protons. The high cold neutron flux at the Los Alamos Neutron Scattering Center (LANSCE) spallation neutron source and control of systematic errors require the use of current mode detection with vacuum photodiodes and low-noise solid-state preamplifiers. We show that the detector array operates at counting statistics and that the asymmetries due to B4C and (27)Al are zero to with- in 2 × 10(-6) and 7 × 10(-7), respectively. Boron and aluminum are used throughout the experiment. The results presented here are preliminary.

7.
J Res Natl Inst Stand Technol ; 110(3): 145-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308111

RESUMO

The NPDGamma collaboration has completed the construction of a pulsed cold neutron beam line on flight path12 at the Los Alamos Neutron Science Center (LANSCE). We describe the new beam line and characteristics of the beam. We report results of the moderator brightness and the guide performance measurements. FP12 has the highest pulsed cold neutron intensity for nuclear physics in the world.

8.
J Res Natl Inst Stand Technol ; 110(3): 309-13, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308142

RESUMO

The abBA collaboration is developing a new type of field-expansion spectrometer for a measurement of the three correlation coefficients a, A, and B and the shape parameter b. The measurement of A and B requires precision neutron polarimetry. We will polarize a pulsed cold neutron beam from the SNS using a (3)He neutron spin filter. The well-known polarizing cross section for n-(3)He has a 1/v dependence, where v is the neutron velocity, which is used to determine the absolute beam polarization through a time-of-flight (TOF) measurement. We show that by measuring the TOF dependence of A and B, the coefficients and the neutron polarization can be determined with a small loss of the statistical precision and with negligible systematic error. We conclude that it is possible to determine the neutron polarization averaged over a long run in the neutron beta decay experiment with a statistical error less than 10(-4). We discuss various sources of systematic uncertainty in the measurement of A and B and conclude that the fractional systematic errors are less than 2 × 10(-4).

9.
J Res Natl Inst Stand Technol ; 110(4): 361-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308151

RESUMO

We present a conceptual design for an experiment to measure the neutron lifetime (~886 s) with an accuracy of 10(-4). The lifetime will be measured by observing the decay rate of a sample of ultracold neutrons (UCN) confined in vacuum in a magnetic trap. The UCN collaboration at Los Alamos National Laboratory has developed a prototype UCN source that is expected to produce a bottled UCN density of more than 100/cm(3) [1]. The availability of such an intense source makes it possible to approach the measurement of the neutron lifetime in a new way. We argue below that it is possible to measure the neutron lifetime to 10(-4) in a vacuum magnetic trap. The measurement involves no new technology beyond the expected UCN density. If even higher densities are available, the experiment can be made better and/or less expensive. We present the design and methodology for the measurement. The slow loss of neutrons that have stable orbits, but are not energetically trapped would produce a systematic uncertainty in the measurement. We discuss a new approach, chaotic cleaning, to the elimination of quasi-neutrons from the trap by breaking the rotational symmetry of the quadrupole trap. The neutron orbits take on a chaotic character and mode mixing causes the neutrons on the quasi-bound orbits to leave the trap.

10.
J Res Natl Inst Stand Technol ; 110(4): 389-93, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308155

RESUMO

We are developing an experiment to measure the correlations a, A, and B, and the Fierz interference term b in neutron decay, with a precision of approximately 10(-4). The experiment uses an electromagnetic spectrometer in combination with two large-area segmented silicon detectors to detect the proton and electron from the decay in coincidence, with 4π acceptance for both particles. For the neutron-polarization-dependent observables A and B, precision neutron polarimetry is achieved through the combination of a pulsed neutron beam, under construction at the SNS, and a polarized (3)He neutron polarizer. Measuring a and A in the same apparatus provides a redundant determination of λ = gA/gV . Uncertainty in λ dominates the uncertainty of CKM unitarity tests.

11.
J Res Natl Inst Stand Technol ; 110(4): 427-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308162

RESUMO

We have developed a new type of field-expansion spectrometer to measure the neutron beta decay correlations (a, b, B, and A). A precision measurement of these correlations places stringent requirements on charged particle detectors. The design employs large area segmented silicon detectors to detect both protons and electrons in coincidence. Other requirements include good energy resolution (< 5 keV), a thin dead layer to allow observation of 30-keV protons, fast timing resolution (~1 ns) to reconstruct electron-backscattering events, and nearly unity efficiency. We report results of testing commercially available surface-barrier silicon detectors for energy resolution and timing performance, and measurement of the dead-layer thickness of ion-implanted silicon detectors with a 3.2 MeV alpha source.

12.
Phys Rev Lett ; 93(10): 105302, 2004 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-15447413

RESUMO

We describe a neutron radiography technique that can be used to map the distribution of 3He impurities in liquid 4He, providing direct and quantitative access to underlying transport processes. Images reflecting finite normal- and superfluid-component 4He velocity fields are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...